Features | |||
◆ Wide range of AC input voltage 90-264VAC | |||
◆ Protections against: short circuit/over current/over voltage | |||
◆ Meets 4KV surge immunity | |||
◆ Meets energy star level VI & CoC V5 Tier 2(2016) | |||
◆ PLC power line carrier communication; | |||
◆ Electromagnetic compatibility performance excellent: | |||
CE margin 12dB above, RE margin 8dB above; |
Input Voltage Range | 90-264VAC | Operation Temperature | -10~70℃ | |||||||
Input Current | 800mA | Storage Temperature | -40~70℃ | |||||||
Average Efficiency | Meets energy star level VI & CoC V5 Tier 2(2016) | Humidity | 5% to 95% non condenising,Meets 5000m Elevation | |||||||
Output Voltage Range | ±5% | MTBF | 100,000 hours at full load at 25℃ ambient, calculated per MIL-HDBK-217 | |||||||
Standby Power | 0.075W | |||||||||
Safety Standard | CB; IEC60950; IEC60065; EN62368 | |||||||||
Weight | 75g | Dimensions | 90.0mm (L) ; 45.0mm (W) ; 23.5mm (H) | |||||||
Applications | PLC power line carrier communication、 ITE Equipment |
Output data (UES24-SPA-OP) | |||||
Model | Voltage | Current | Ripple |
| Av.Eff. |
UES24-120YYYSPA-OP | 12.0 | 0.1-2.0 | 120 | Y Y | 86.8 |
Standard | ||
EMC standard | EN55032/CISPR22; EN55024/CISPR24 | |
Conducted & Radiated | EN55032/FCC Part 15 Class B | |
Harmonic Currents | IEC/EN 61000-3-2 Class A | |
Voltage Flicker | IEC/EN 61000-3-3 | |
ESD | IEC/EN 61000-4-2 ±8kV Air, ±4kV Contact | |
Radiated Immunity | IEC/EN 61000-4-3 3V/m | |
EFT/Burst | IEC/EN 61000-4-4 ±2kV | |
Surge | ITU-T K.21/IEC/EN 61000-4-5 ±4KV diff. mode, ±4KV common Mode | |
Conducted Immunity | IEC/EN 61000-4-6 3Vrms | |
Dips & Interruptions | IEC/EN 61000-4-11 0%, 70%, 0% of UT |